Loading...
  • Home
  • Search Results
2083-2084 of 4327 Papers

ENHANCING SOFTWARE PIRACY AND INTEGRITY PROTECTION IN CLOUD COMPUTING WITH TPM

Published In: 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN INFORMATION PROCESSING AND COMMUNICATION TECHNOLOGY
Author(s): ABOUELMEHDI KARIM , EL AMRANI FATIMA ZOHRA , EL FEZAZI SAID , HEDABOU MUSTAPHA

Abstract: Software as a Service (SaaS) is a kind of *aaS distribution and deployment model in which applications are provided to customers as a service. The applications can run on the user’s computing systems or the CSP’s Web servers. The solution may belong to a software company, which host it among a CSP and offer it as instances to customers. As mentioned [1] software piracy is the major concern of software’s publisher; lot of solution has been set up, but editors still suffer and lot of copies was made or the solution was cracked. Our proposed design demonstrate how software protection can be protected from redistribution and tampering. The aim is to secure instance access through the new specification of TPM 1.2[13] that is time stamping to have the exclusive access to an instance or result of software computation, so only one person can have the access. Besides the new design, combined to the TCCP design [12] protects side channel attacks and/or attacks from the sysadmin.

  • Publication Date: 11-Dec-2015
  • DOI: 10.15224/978-1-63248-077-4-13
  • Views: 0
  • Downloads: 0

DESIGNING AND PERFORMING OF SERUM FLOW RATE BY MICROCONTROLLER

Published In: 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN INFORMATION PROCESSING AND COMMUNICATION TECHNOLOGY
Author(s): FECIR DURAN , M. RAHMI CANAL , MERAL OZARSLAN YATAK , SABRI KOCER , SERDAL GUVENC

Abstract: Drug injection together with serum to vessel of patient is one of drug treatment (medication) methods. In this method it is necessary that drug must be given on the certain frequencies and within certain dosages during treatment to patient. Therefore serum should be injected to patient by very sensitive systems. In performed study control of serum flow rate was carried out by drop counting method without using another addition piece apart from standard serum sets. Because of control process of flow rate was performed the that way, automatically compressing and losing by engine of serum hose, any physical interference which would be made to serum system was blocked. Hereby more sterile treatment environment was created. Additionally there was provided possibility for more sensitive treatment while user inform is performed by LCD screen which is placed on it.

  • Publication Date: 11-Dec-2015
  • DOI: 10.15224/978-1-63248-077-4-14
  • Views: 0
  • Downloads: 0